TOP302
folderedge.jpg
Brick / Wood Fire Rating
folderbar.jpg

[HOME] [TECH LIBRARY] [FIRE SAFETY] [Masonry UL Ratings] [Brick Fire Ratings]

Related External Links

BIA Tech Note 16

NCMA Techical Notes

BIA Tech Note 16b

UL Web Site

 

Brick & Wood Stud

UL Fire Ratings

Search for Masonry Articles

 

 

UL Number

Fire Rating

Description of Assembly

U302

2 Hours

Brick Veneer / Wood Stud, Loadbearing

  • (2) layers ⅝ in. (15.9 mm) thick gypsum wallboard or nominal 3⁄32 in. (2.4 mm) thick gypsum veneer plaster on Classified veneer baseboard
  • (1) layer in. (12.7 mm) thick exterior gypsum sheathing
  • 1 (25.4 mm) in. (51 102 mm) air space
  • nominal 2 4 in. wood studs spaced at 16 in. (406 mm) o.c.
  • nominal 4 in. (102 mm) clay facing brick laid in mortar with in. (19.1 mm) wide 6⅝ in. 168mm) long 20 MSG corrugated wall ties spaced at 16 in. (406 mm) o.c. each way

U356

1 Hour

Brick Veneer / Wood Stud, Loadbearing

  • (1) layer ⅝ in. (15.9 mm) thick gypsum board
  • nominal 2 4 in. (51 102 mm) wood studs spaced at 16 in. (406 mm) o.c., with 3 in. (89 mm) thick glass fiber batt or spray applied cellulose insulation
  • 7⁄16 in. (11.1 mm) min. thick wood structural panels or min. in. (12.7 mm) thick mineral and fiber boards
  • 1 in. (25.4 mm) air space
  • nominal 4 in. (102 mm) brick veneer with corrugated metal wall ties spaced not more than each sixth course of brick and max. 32 in. (813 mm) o.c. horizontally

U35

1 Hour

Brick Veneer / Wood Stud, Loadbearing

  • (2) layer ⅝ in. (15.9 mm) thick gypsum board
  • nominal 2 4 in. (51 102 mm) wood studs spaced at 16 in. (406 mm) o.c. with min. 3 in. (76 mm) mineral wool batt insulation
  • (1) layer ⅝ in. (15.9 mm) thick gypsum board
  • 1 in. (25.4 mm) air space
  • nominal 4 in. (102 mm) brick veneer with corrugated metal wall ties attached with screws and spaced not more than each fourth course and a max. 24 in. (610 mm) o.c. horizontally